宫腔镜下能源电针分离与微型机械分离在治疗中、重度宫腔粘连中的疗效比较
投稿时间:2018-01-23  修订日期:2018-03-21  点此下载全文
引用本文:吴丽莉,李新,洪莉.宫腔镜下能源电针分离与微型机械分离在治疗中、重度宫腔粘连中的疗效比较[J].医学研究杂志,2018,47(12):125-128,173
DOI: 10.11969/j.issn.1673-548X.2018.12.029
摘要点击次数: 838
全文下载次数: 739
作者单位E-mail
吴丽莉 430060 武汉大学人民医院妇产科  
李新 430060 武汉大学人民医院妇产科  
洪莉 430060 武汉大学人民医院妇产科 drhongli1011@yeah.net 
中文摘要:目的 探讨宫腔镜下能源电针分离术与微型剪刀机械分离术治疗中、重度宫腔粘连的疗效。方法 回顾性分析中、重度宫腔粘连患者76例,按手术方式分为两组,其中机械组36例,术中给予微型剪机械分离,能源组40例,给予等离子电针分离。比较两组术中手术时间、出血量、术后月经恢复情况、子宫内膜厚度及子宫腔形态、宫腔容积、术后妊娠情况。结果 能源组20.05±7.30ml的术中出血明显少于机械组32.30±13.3ml,能源组14.75±3.43min的手术时间明显少于机械组26.39±5.39min(P<0.05)。能源组对宫腔形态恢复的满意率95%高于机械组83.3%(P<0.05)。能源组月经恢复率95.0%高于机械组83.3%(P<0.05)。能源组术后宫腔容积4.76±0.78ml高于机械组4.30±0.76ml(P<0.05),能源组术后子宫内膜厚度6.35±1.30mm高于机械组5.18±1.76mm(P<0.05)。能源组妊娠率为57.5%高于机械组33.3%(P<0.05)。结论 宫腔镜下能源电针分离术治疗中、重度宫腔粘连具有良好的疗果,值得临床推广。
中文关键词:中、重度宫腔粘连  宫腔镜下能源分离术  宫腔镜下机械分离术  宫腔形态  妊娠率
 
Comparion of Efficacy between Hysteroscopic Energy Electroacupuncture Separation and Micro-hysteroscopic with Cold Loop in the Treatment of Moderate to Severe Intrauterine Adhesions
Abstract:Objective To investigate the efficacy of hysteroscopic energy electroacupuncture and hysteroscopic with cold loop of micro-scissors in the treatment of moderate to severe intrauterine adhesion. Methods A total of 76 patients diagnosed with severe intrauterine adhesions were divided into two groups according to the surgical method. Totally 36 cases of the energy group use the micro shear hysteroscopic with cold loop, while 40 cases of the mechanical group using plasma electroacupuncture separation. The operation time, blood loss, postmenstrual recovery, endometrial thickness and uterine cavity morphology, uterine volume, and postoperative pregnancy were compared between the two groups. Results The intraoperative bleeding in the energy group 20.05±7.30ml was significantly less than that in the mechanical group 32.30±13.3ml, and the operation time in the energy group 14.75±3.43min was significantly less than that in the mechanical group 26.39±5.39min(P<0.05). The satisfaction rate of the energy group on morphological recovery(95%) was higher than that of the mechanical group 83.3%(P<0.05). The menstrual recovery rate of the energy group(95%)was higher than that of the mechanical group 83.3%,(P<0.05). The uterine volume 4.76±0.78ml in the energy group was higher than that in the mechanical group 4.30±0.76ml (P<0.05), and the endometrial thickness 6.35±1.30mm in the energy group was higher than that in the mechanical group 5.18±1.76 mm (P<0.05). The pregnancy rate of the energy group(57.5%)was higher than that of the mechanical group 33.3%(P<0.05). Conclusion Hysteroscopic energy electroacupuncture separation for the treatment of moderate to severe intrauterine adhesions has a good therapeutic effect and is worthy of clinical promotion.
keywords:Moderate-to-severe intrauterine adhesions  Hysteroscopic with electric loop  Hysteroscopic with cold loop  Uterine cavity shape  Pregnancy rate
查看全文  查看/发表评论  下载PDF阅读器

京公网安备 11010502037822号